The MULTImate can be used to program MULTIPLEX RX-SYNTH IPD receivers.
Note: The voltage of the power supply must be at least 4.8 V!
• Connect the receiver (socket "B/D") to the PC and Data port on one end of the MULTImate using the data lead sup-
plied in the set.
Action & Display
2 RX-Synth IPD
2-1 RF-Channel
068 – 35,080 MHz
2-2 Servochannel
7
2-3 Failsafe
2-4 Hold length
0.5 sec
MULTIPLEX Modellsport GmbH & Co.KG • Westliche Gewerbestraße 1 • D-75015 Bretten (Gölshausen) • www.multiplex-rc.de
Operating Instructions - MULTImate – V1.42
IPD
2
Go back
...to main menu
2-3 Go back
...to RX IPD
2-3 Servo 1
L
< FS off >
(...)
(...)
2-3 Servo 4
L
<< 1453 µs
(...)
(...)
2-3 Servo 12
not available
2-3 FS length
15.0 sec
Explanation
Main menu display "2 RX-Synth IPD"
Display of the set RF channel
(channel cannot be changed).
Note: display after receiver reset:
"RF-Channel Chan. Search" or "HF-Kanal Kanalsuche"
Servo channel display
and / or transmission format of the transmitter in use
(setting cannot be changed).
Note: display after receiver reset:
"Servochannel No signal" or "Servokanäle kein Signal"
Selecting the Fail-Safe setting for servos 1, ..., 12
Select servo 1, ..., 12 using
Change the fail-safe setting for the selected servo:
• Fail-safe for each servo "on" / "off" or "ein" / "aus":
• Change fail-safe setting:
and
or
, confirm with
Note: After receiver reset Fail-Safe is "off" or "aus"
Selecting the Fail-Safe period (max. fail-safe period
after hold period has elapsed)
Can be selected from 0.0 sec to 24.0 sec.
Change value using and
selected value with
or
or
, confirm the
Seite 6/22