Before using any detergents inquire with your family supplier about neutral products without chlorine, in order
to avoid corrosions of the steel. In case of scratches on the surface it is necessary to smooth it with the finest
stainless steel wool or with abrasive cloth made of sinewy synthetic material.
For the cleaning of the stainless steel it is recommended not to use steel wool and do not leave them on it
because little ferrous deposits might remain on the surface and therefore it could cause the making of rust and
compromise the hygiene conditions.
Attention, during the cleaning operations it is recommended to use work gloves.
ATTENTION
The operations of ordinary and extraordinary maintenance are described on the chapter
"5 MAINTANANCE - GARBAGE MANAGEMENT - DISPOSAL OF MATERIALS" Pag. 34.
4 RECOMMENDATIONS AND WARNINGS
ATTENTION
This professional equipment may only be used and cleaned by adults (> 18 years of age in Europe or other limits
defined by local legislation) in normal physical and psychological condition and who have been adequately
trained and informed regarding health and safety in the workplace. The professional equipment may also be
used by trainees, in work/school projects, according to local legislation, provided that, they are under strict su-
pervision by a tutor and are adults as mentioned above. In other words, trainees must be in normal physical and
psychological condition, and adequately trained and informed regarding health and safety in the workplace.
We recommend to make a daily cleaning of the external part of the blast chiller, including the internal side of
the door near the gaskets.
ATTENTION
Do not place hot pans, hot pots or any hot object on top or close to the the equipment.
Blast chillers | User and maintenance manual | EN
In order to have always a good function of the condensing unit it is neces-
sary to carry out periodically the condenser cleaning. This cleaning de-
pends mostly on the environment where the condensing unit is installed.
It is advisable to use an air flush blowing from the inside to the out-
side of the unit. If it was not possible, use a long bristle brush on the
external of the condenser. Be careful not to damage the circuit of
the cooling fluid. The built in condensing unit is placed in the lower
side of the blast chiller. Do not use water splashes.
33