EN | Blast chillers | User and maintenance manual
ATTENTION
READ INSTRUCTION
ENGLISH - RAEE - Electrical and Electronic Waste Management
The barred can symbol displayed on the product or in the use manual documentation indicates that the product has been placed for sale on the market after August 13, 2005. At
the end of its useful life-cycle, the product must be collected, disposed of, and transported separately from urban waste, in accordance to the norms in force in each individual country.
RAEE
In this way, it can be recovered, contributing to avoid possible negative effects on the environment and health, and favoring the re-use and/or recycling of the materials of which the
WEEE
equipment is made of. The abusive disposal of the product by the user entails the application of administrative sanctions established by the norms in force. The EU Directive RAEE
N. 2002/96/CE, (implemented in Italy by the Law Decree n. 151 dated May 15, 2005); EU Directive N. 2003/108/CE concerning the handling of electrical and electronic waste.
CLIMATE CLASS : 5 (Ambient temperature +40°C; Relative humidity 40%)
MAX SHELF LOAD : 15 kg (uniformed distribuited load)
Any operation of ordinary and extraordinary maintenance of the equipment
must be done disconnecting the electric power supply. This maintenance
must be done by qualified technician.
The plug has to be always connected to a fixed outlet. It is strictly forbidden
to connect the equipment plug to an extension cord or an adapter.
Do not damage or bend the evaporator fins or tubes of the coolant.
This professional equipment may only be used and cleaned by adults (> 18
years of age in Europe or other limits defined by local legislation) in normal
physical and psychological condition and who have been adequately trained
and informed regarding health and safety in the workplace.
The professional equipment may also be used by trainees, in work/school
projects, according to local legislation, provided that, they are under strict
supervision by a tutor and are adults as mentioned above. In other words,
trainees must be in normal physical and psychological condition, and adequately
trained and informed regarding health and safety in the workplace.
The installation of the device and of the refrigerator unit must be done
only by the manufacturer's technicians or by trained personnel.
If the power supply cable is damaged, it must be substituted by the
manufacturer or by its technical assistance service.
At the end of the positive process phase, the conservation program is
set automatically at the temperature of 0 to +3°C.
At the end of the negative process phase, the conservation program is set
automatically at the temperature of -22 to -25°C.
In order to respect the chilling and freezing time provided by law, while a cycle
is in progress, it is strongly advised against opening the door of the device.
When parts are being replaced and when removal of the plug is foreseen, and
removal of the plug is clearly indicated, it must be such that an operator may
check, from any point to which he has access, that the plug remains disconnected.
All maintenance operations, repairs and cleaning, must be carried out
with the unit in stop position and with the power switched off.
UP
24
Welcome
The producer thanks you for choosing one of its products.
We kindly ask you to read carefully our manual: this will guarantee the optimal use of your equipment.
DOWN
SET
Translation of the original instructions
START / STOP
EARTHING
ATTENTION