Tecnodom Attila LISTRABT Notice D'utilisation page 29

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 46
1.5 POSITIONING AND FEET REGULATION
1.6 INSTALLATION INSIDE YOUR SHOP/RESTAURANT /WORKROOM
We suggest you to install the blast chiller/freezer inside an air-conditioned room. We kindly remind you that
without this facility, malfunction may occur (for example condensation etc).
ATTENTION
In order to allow a good functioning of the blast chiller/freezer please draw attentions to the following
instructions.
Do not place the blast chiller/freezer to a direct exposure of sunlight and to all the other
means of irradiation, such as high intensity incandescent lights, cooking ovens, heating radiators.
Do not place the blast chiller/freezer close to external exits into draught, such as doors, win-
dows, air vent or air conditioning fans.
Do not obstruct the blast chiller/freezer air inlet.
Do not place any kind of material on the blast chiller. Keep clear the whole blast chiller/freezer
perimeter in order to allow a proper air circulation.
Do no place the blast chiller/freezer into an high relative humidity room (condensate water
creation is possible).
Do not place the blast chiller/freezer inside a closed cavity. Without a proper air circulation the
refrigeration unit will not work efficiently.
Do not place hot trays or pans on the top of the blast chiller.
Do not place hot pans, hot pots or any hot object on top or close to the the equipment.
Verify that in the installation room there is enough air turnover, even during closing and rest hours. In
this way the expansion/condensing unit will work correctly.
1.7 MINIMUM WALL DISTANCE
In order to allow a good blast chiller/freezer functioning and a correct air circulation, during the positioning you
have to respect some minimum wall distance as follows:
Keep a minimum distance, corresponding to the door opening length, from the front unit grid view.
Keep a minimum 10 cm distance of the blast chiller back from the wall.
Place the blast chiller/freezer in a perfect horizontal position, acting if necessary on
the screw type adjustable feet. Use a spirit level to check it. The blast chiller/freezer
must be placed in order to operate properly and allow the correct defrost conden-
sate water draining. In this way you will avoid noisy vibrations of the condensing unit.
Check the correct positioning of the condensate water basin and its draining.
Blast chillers | User and maintenance manual | EN
29

Publicité

Table des Matières
loading

Table des Matières