24 V DC design
7.4
Opening/Closing the housing
Opening:
→
Remove lead seal if housing is secured.
→
Open the plastic hood by turning it anticlockwise (all the way,
approx. 1.5 cm).
Closing:
→
Put the plastic hood on the lower part such that the inner "lugs"
are positioned over the locking grooves and the external sealing
lugs are positioned almost over each other. Press the hood
completely over the seal of the lower part (see "Fig. 1").
→
Turn the hood by approx. 1.5 cm clockwise (meaning until the
sealing lugs are positioned over each other).
A lead seal is required on the hood in potentially explosive
atmospheres!
7.5
Electrical installation
See chapter:
" 8 24 V DC design",
"9 AS-I design",
"10 DeviceNet design",
"11 120 V AC design",
"12 büS / CANopen design",
"13 IO-Link design".
Type 8681
8
24 V DC DESIGN
8.1
Connection options
Connection left:
1 x M16 x 1.5 cable gland for
power supply and signals
Connection right:
1 x M16 x 1.5 cable gland for
external initiator
8.2
Electrical data
Power supply:
Power consumption
(standby current):
english
Connection left:
1 x M16 x 1.5 cable gland with
multipole connection (M12 plug
according to IEC 61076-2-101,
12-pole) on a cable of 8 cm
Connection right:
1 x M16 x 1.5 cable gland for
external initiator
12 ... 28 V DC, residual ripple 10%
30 mA at 24 V DC
13