Final Checks; User Instruction - Erreka FENIX Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

STARTING UP AND PROGRAMMING
Slowdown distance (
1 Keep the |+ button pressed down until the display
P
shows
.
2 Release the button |+ : the display will show
3 Press the button |+ until the display shows
press SET to confirm.
The display shows 3 (predetermined value).
Fixed code (trinary) or roller code transmitter (
1 Keep the |+ button pressed down until the display
P
shows
.
2 Release the button |+ : the display will show
3 Press the button |+ until the display shows
press SET to confirm.
The display shows 6
6

FINAL CHECKS

Following installation and programming, start up the
operator and check the devices installed.
1 Check the correct operation of the key commands
(push button and wall key, remote control).
See "Operation modes" on page 50.
2 Check the correct operation of the safety devices
(photocells).
See "A- Detection by the additional safety device
(photocell)" on page 51.
3 Place an obstacle and make the door collide with it
in order to check operation in the event of collision.
See "B- Direct detection (sensitiveness of the
actuator)" on page 51.
If the system does not work correctly, find out
why and put it right (see section "Failure
diagnosis" on page 65).
64
Installation Manual
5
)
1
.
5
and
1
.
6
and
).
(flashing
4 Press |+ and |- to select the required value:
1: without slowdown
2: slowdown, distance 20mm (measured in the
track
3: slowdown, distance 100mm (measured in the
track
4: slowdown, distance 250mm (measured in the
track)
5 Press SET to confirm.
The display will flash
will show H or h (programming mode complete).
6
)
4 Press |+ and |- to select the required value:
F: trinary, fixed code
r: standard roller code
r.: personalised roller code
5 Wait for 1 second.
The display will flash
will show H or h (programming mode complete).

User instruction

1 Instruct the user with regards to the use and
maintenance of the installation and provide him/her
with the instructions on use.
2 Signpost the door, showing that it opens
automatically and indicating how to operate it
manually.
Where
appropriate,
operation is using the remote control.
5
and after a few instants
6
and after a few instants
indicate
that

Publicité

Table des Matières
loading

Table des Matières