LEROY-SOMER
7.11 - Parameter-setting
console (PX LCD)
the console option provides access to the drive internal
settings (terminal block configuration, ramp, speed and PI
settings, etc).
see VaRmeca 30 parameter-setting manual.
Description of the option:
1 PX lcD console, 1 cable l = 3 m
PX LCD parameter-setting console
7.12 - Parameter-setting software
(VMA SOFT)
this option provides access to the drive internal settings from a
Pc. the software is compatible with WInDoWs 7.
see VaRmeca 30 parameter-setting manual.
Description of the option:
1 cable l = 1.5 m
the software can be downloaded directly from the Web :
www.leroysomer.com.
7.13 - Operator display (PAD VMA 30)
Presentation of the operator display :
the PaDVma30 operator display consists of a display unit,
three control buttons and three parameter-setting keys.
Ref.
Display comprising 4 x 7-segment digits for
indicating:
- the drive operating status
a
- certain operating data
- the adjustment parameters (01 to 80)
and their value.
leD providing a sign for the data (the lit leD
B
corresponds to the «-» sign).
Keys which can be used to scroll up and down
through the parameters or their value. these keys
c
can also be used to vary the speed.
Keys which can be used to switch from standard
mode to parameter-setting mode.
D
In parameter-setting mode, the parameter number
and value are displayed alternately on the display.
In keypad mode, these buttons are used for the
following commands:
e
- reverse,
- stop, clear fault,
F
- forward.
G
the parameter setting to use the PaD Vma30 is described in
the Parameter setting document 3847.
InstallatIon anD maIntenance
VARMECA 30
Variable speed motor or geared motor
Function
7.14 - XPress Key (PX Key)
7.14.1 - General
the XPress Key option is used to save a copy of all the
VaRmeca 30 parameters so that they can be duplicated very
simply in another drive.
7.14.2 - Setting drive parameters with XPress
Key
• connect XPress Key to the serial port via a RJ45 connector.
• With the drive locked, press the «Key» button for a first time.
confirm the transfer of parameters into the drive by pressing
the «Key» button a second time.
CAUTION: If confirmation is not received within
10 seconds, the procedure is cancelled.
VARMECA PADVMA30
A
B
E
F
G
3776 en -
2013.06 / k
C
D
29