Volt-Ampere Curves; Remote 6 Receptacle Information (Stl And Sth Models Only) - Miller Maxstar 150 S Manuel De L'utilisateur

Masquer les pouces Voir aussi pour Maxstar 150 S:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3-3. Volt-Ampere Curves

100
80
60
40
TIG Min
20
Stick Min
0
0
50

3-4. Remote 6 Receptacle Information (STL And STH Models Only)

OM-2242 Page 8
Volt-ampere curves show minimum and maximum voltage and amperage output capabilities
of welding power source. Curves of other settings fall between curves shown.
115 VAC Input
TIG/Stick Max
100
150
Amperes
15 VOLTS DC
15 VOLTS DC
REMOTE
REMOTE
OUTPUT
CONTROL
CHASSIS
100
80
60
40
20
0
200
0
50
Socket
6
1
Contactor control +13.8 volts DC.
2
Contact closure to 1 completes contactor control
OUTPUT
circuit and enables output when Lift-Arc TIG re-
CONTACTOR
mote is selected.
3
Output to remote control; +10 volts DC output to
remote control.
4
0 to +10 volts DC input command signal from
remote control.
5
Remote control circuit common.
6
Chassis common.
230 VAC Input
TIG/Stick Max
TIG Min
Stick Min
100
150
Amperes
Socket Information
200
208 604-B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Maxstar 150 stlMaxstar 150 sth

Table des Matières