CP6632
Voltage or current generation // incremental editing?
Press key F2 to display the edit menu.
Using the navigation keys (↑ ↑ ↑ ↑ and ↓ ↓ ↓ ↓ ), select the INCREMENTS
editing mode and confirm (VAL key).
The value displayed is that programmed in the CONFIGURATION/RAMP menu
(see next chapter).
Using the navigation key (↑ ↑ ↑ ↑ ), start the automatic incrementing phase
(according to the parameters programmed in the
CONFIGURATION/RAMP menu).
The voltage can be automatically decremented from the
programmed maximum value using the navigation key (↓ ↓ ↓ ↓ ).
The transmitted voltage can be manually incremented (according to
the parameters programmed in the CONFIGURATION/RAMP
menu) using the navigation key ( ).
The transmitted voltage can be manually decremented from the
maximum programmed value using the navigation key (    ).
Voltage or current generation / single ramp editing?
Press key F2 to display the edit menu.
Using the navigation keys (↑ ↑ ↑ ↑ and ↓ ↓ ↓ ↓ ), select SINGLE RAMP editing
mode and confirm (VAL key).
The value displayed is that programmed in the CONFIGURATION/RAMP menu
(see next chapter).
Using the navigation key (↑ ↑ ↑ ↑ ), start the automatic incrementing phase
(according to the parameters programmed in the
CONFIGURATION/RAMP menu).
The voltage can be automatically decremented from the
programmed maximum value using the navigation key (↓ ↓ ↓ ↓ ).
The transmitted voltage can be manually incremented (according to
the parameters programmed in the CONFIGURATION/RAMP
menu) using the navigation key ( ).
The transmitted voltage can be manually decremented from the
maximum programmed value using the navigation key (    ).
The Hold key allows generation to be stopped and restarted
Ramp generation can be done step by step by pressing the navigation keys
) and automatic generation restarted with the navigation keys (↑ ↑ ↑ ↑
(    and
and ↓ ↓ ↓ ↓ ).
Transmission can be delayed by a programmable length of time (in the
CONFIGURATION/RAMP/DELAY menu)
Voltage or current generation / cyclic ramp editing?
Press key F2 to display the edit menu.
Using the navigation keys (↑ ↑ ↑ ↑ and ↓ ↓ ↓ ↓ ), select CYCLIC RAMP editing
mode and confirm (VAL key).
The value displayed is that programmed in the CONFIGURATION/RAMP menu
(see next chapter).