13 Specimen Installation
This specimen installation is intended to explain the use of
Terxon SX.
UK
Here we use a system with two users. One user
(de)activates the alarm system using code input, the other
with a chip key.
Furthermore, two sensors, a motion sensor (XEVOX
ECO) and door/window contacts (FU7350W) are
connected to the system. The complete system is armed
using the key-switch (SE1000).
The SG1650 signalling device (siren+flashlight) is used for
visual and acoustic signalling of an intrusion or panic
alarm.
We also wish to explain in detail the programming of the
sensor types and of the transistor outputs for the external
alarm signalling equipment. Do not connect the equipment
yet to the mains power supply or the battery!
We start with the wiring of the alarm lines of the motion
sensor and door contacts. This is followed by an
explanation of the wiring of the tamper line.
Please use the 8-core alarm cable AZ6360 or AZ6361 for
connecting up. The following diagram shows how the
sensors are connected to the alarm centre:
Note that you need two extra lines for connected the
tamper line.
In the next step, we connect the control unit to the system.
Note that the jumper is not connected if only one control
unit is used (see page 13). Connect the control unit to the
alarm centre as shown.
Now connect the key switch (SE1000) to the system.
Then connect the cable supplied in the scope of delivery
to the connecting strip for the additional switching outputs.
These outputs are required for controlling the LEDs.
Please read the operating instructions of the SE1000.
Please take care that you use the pulse setting for the
keyswitch. The circuit shown above enables you to
24