1A AUX fuse for
power supply
2A BAT fuse for
battery charging
Kick
AC
Battery
star
connector of
connector
transformer
Programmable transistor outputs
(OP). Max. power consumption of all
transistor outputs 0.5A.
Connection
AC mains supply unit (AC IN)
Kick Start jumper (KS)
Battery contact (+ -)
COMMS interface
Reset jumper (NVM RST)
Fuses (BAT F-2A / 12VAUX F-
1A)
Siren sabotage input (TR)
Optional loudspeaker (LS)
COMMS
interface
NVM
Lid tamper contact
EEPROM
Tamper input for external
components (e.g.
12V power supply for
external components (e.g.
Meaning
Contact for 230V main supply unit
Connect the two contacts of this jumper to start the alarm centre without a 230V mains
power supply.
Connecting plug from standby power supply
Contact for additional transistor outputs
Connect the two contacts of this jumper to reset the alarm centre.
Always use fuses of the same type. To avoid problems, make sure there is always a good
contact between the fuse holder and the fuse.
For sirens with their own power supply, connect this input direct to the tamper output of the
siren. Otherwise, connect the tamper contact of the siren to the loop between the TR input
and 0V. If no siren is used, connect the TR input direct to the 0V output.
Connect a 16 Ohm loudspeaker for internal alerts.
15
Alarm zone 1–8 for NC alarm contacts (e.g.
IR sensor). No NO contacts can be
connected. Make sure the alarm zones are
terminated with the corresponding resistors.
Either two different resistors or no resistor
must be used, depending on programming.
If the zone is used, remove the wire jumper.
UK
Control unit