Control Box Terminal Blocks; Control Selection (Dry Contact Control / Ac Control) - SOMFY HiPro-FTS 50 Notice D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
50112069
8
X01 - EH

11. Control box terminal blocks

FUSE
1
3
2
Power supply
1: Live
2: Neutral
3: Shared by actuators (blue wires from straps and
fabric actuators)
Do not feed the actuators power supply cables and the control and safety cables through the same sheath.
The earth wires (yellow/green) from the 2 actuators must be connected to the power supply earth on 1 electric split fitting
separate from the circuit and AC control earth wire if using one.
One-touch control via double push buttons (stop by pressing both push buttons).

12. Control selection (Dry contact control / AC control)

Only one kind of control should be installed on the control box.
The control point must be class II.
To select the dry contact control
mode, push the Dry contact switch to
the «on» position (right) and connect
the control to the terminal 13/14/15.
To select the AC control mode,
connect the control to the terminal
10/11/12.
The system must be reset by cutting of the power in order to activate the change.
10
5034918A_FTS.indb 10
5
7
9
11
13 15
4
6
8
10
12
14 16
ON
ON
OFF
OFF
0
0
OFF
OFF
0
0
Straps actuator
4: Straps winding (black or brown wire
from actuator)
5: Straps tension (brown or black wire from actuator)
6: Straps electro-brake (grey wire from actuator)
Fabric actuator
7: Fabric winding (black or brown wire from actuator)
8: Fabric tension (brown or black wire from actuator)
9: Fabric electro-brake (grey wire from actuator)
230V AC Control connector
FUSE
10: Brown wire
11: Blue wire
12: Black wire
Control + safety
13: Control shared
14: Fabric unwinding control
15: Fabric winding control
16: Aperture safety (if not used, leave electric bridge
between terminals 13 and 16)
ON
OFF
FUSE
FUSE
Copyright © 2013 - 2017 Somfy SAS. All rights reserved.
ON
ON
OFF
OFF
WARNING
Contact will cause
electric shock
08
WARNING
Contact will cause
electric shock
ON
08
OFF
0
0
-
C
+
ON
ON
OFF
OFF
50112069
X01 - EH
0
0
FUSE
ON
ON
OFF
OFF
50112069
X01 - EH
0
0
FUSE