Subject
Specification
Dynamic
Max. admissible unbalance Upper
according to ISO 1940/1, Balance
Balancing
Quality Grade G6.03
ELECTRICAL DATA
Discotom-60
Voltage/ frequency
3x200-210/50-60
Mains Cable
3x220-230/50
Specification*
3x220-240/60
3x380-415/50
3x460-480/60
*Important:
Local standards may overrule the recommendations for the main supply cable.
If necessary, please contact a qualified electrician to verify which option is suitable for the
local installation setup.
Residual Current
type A, 30 mA (or better) is recommended.
Circuit Breaker
Discotom-65
Voltage/ frequency
3x200-210/50-60
Mains Cable
3x220-230/50
Specification*
3x220-240/60
3x380-415/50
3x460-480/60
*Important:
Local standards may overrule the recommendations for the main supply cable.
If necessary, please contact a qualified electrician to verify which option is suitable for the
local installation setup.
Residual Current
type B time-delayed, 30 mA (or better) is REQUIRED.
Circuit Breaker
EU Directives
Noise level
Environmental
Discotom-60 /-65
Instruction Manual
Cable size
3xAWG12 + PE
3x2,5mm² + PE
3xAWG12 + PE
3x2,5mm² + PE
3xAWG12 + PE
Cable size
3x4mm² + PE
3xAWG8 + PE
3x4mm² + PE
3xAWG8 + PE
3x4mm² + PE
Please refer to the Declaration of Conformity
Approx. 67dB(A) running idle, at a distance of 1.0 m / 39.4" from the
machine.
Upper = 2 gmm/kg = 110 gmm.
Min.
Fuse size
Fuse size
25 A
25 A
25 A
20 A
20 A
Min.
Fuse size
Fuse size
35
35
25
25
35
Max.
40 A
40 A
40 A
40 A
40 A
Max.
Protective
Earth Cable
40
4 mm²
40
AWG 8
40
4 mm²
40
AWG 8
40
4 mm²
59