3-3. Connecting Spool Gun To Millermatic 211

OM-272 384 Page 12
.
Be sure that gun end is tight against drive assembly.
Incorrect installation will have adverse effects on gas flow.
5
Correct
1
3
2
4
Incorrect
1
Drive Assembly
2
Gun Trigger Plug
3
Gun Trigger Receptacle
Route gun trigger plug through front
panel.
Insert plug into receptacle, and
tighten threaded collar.
4
Gun Securing Knob
5
Gun End
Loosen knob. Insert end of gun
through opening in front panel
until it bottoms against drive
assembly. Tighten knob.
Close door.
5
5
Ref. 267 805-A / 267 807-A