3-1. Connecting To Welding Power Source

1
4

3-2. Welding Power Source Settings

Welding Power Source
Model
XMT 304 CC/CV
Invision 304P
XMT 456 CC/CV
Phoenix 456 CC/CV
Invision 456P
XMT 350 CC/CV
SECTION 3 − INSTALLATION
Or
5
6
Mode Switch Setting
Pulsed MIG
No Mode switch - setting auto-
matically done by control unit.
Pulsed MIG
Pulsed MIG
No Mode switch - setting auto-
matically done by control unit.
Pulsed MIG
2
3
ST-801 316-A / Ref. ST-801 192 / ST-801 718 / Ref. 803 691-A
Voltage/Amperage Control
Switch Setting
Remote
No V/A Control switch - setting
automatically done by control unit.
Remote
Remote
No V/A Control switch - setting
automatically done by control unit.
No V/A Control switch - setting
automatically done by control unit.
1
304 Model Welding Power
Sources
2
456 Model Welding Power
Sources
3
XMT 350 Model Welding
Power Sources
4
Remote 14 Cord On Control
Unit
5
14-Pin Extension Cord
(Customer-Supplied)
Use one of these MILLER exten-
sion cords:
043 690 − 25 ft (7.6 m)
043 691 − 50 ft (15.2 m)
.
Make sure total cord length
does not exceed 200 ft (61 m).
6
Wire Feeder
Connect control as shown if you
want control to be close to feeder.
If you want control to be close to
welding power source, connect
control to welding power source,
and connect extension cord be-
tween control cord and feeder.
Set applicable welding power
source controls as explained in
Section 3-2.
Inductance/Dig or
Inductance Control Setting
This control is not functional with
welding power source in Pulsed
MIG mode. Adjust as normal
when welding power source is
used in MIG mode.
Same as above
Same as above
Same as above
Same as above
Same as above
OM-2805 Page 11