OPERATION STAGE ON INPUT 1 AND 2 (BATCH FUNCTION)
Start batch on remote input 1
Stop from output selection formula 00 or
01 from remote input 2
3-40 V
0-1,5 V
Opening
valve
BATCH FORMULA 00
BATCH FORMULA 00
Hold totalizer from remote input 1
Start batch from remote input 2
Start
3-40 V
0-1,5 V
Closing
Opening
valve
valve
INTERRUPTED BATCH
3-40 V
Start
0-1,5 V
Closing
Opening
valve
valve
INTERRUPTED BATCH
3-40 V
BLOCK
0-1,5 V
Hold and reset totalizer from remote input 1
Start batch from remote input 2
Consent mode to batch enable
3-40 V
Start
0-1,5 V
Opening
valve
INTERRUPTED BATCH
BLOCK
0-1,5 V
Closing
Opening
valve
valve
BATCH FORMULA 01
3-40 V
BATCH FORMULA 01
T
Start
Opening
valve
RESTART INTERRUPTED
BATCH
T<1 Sec.
T
T
RESET
Start
Opening
valve
NEW BATCH
Opening
valve
Closing
valve
NEW BATCH
3-40 V
RESET T2
Necessary conditions for enabling the
function
Start
POS. 5.9 ON
Closing
POS. 6.1 or 6.4 on END BATCH
valve
POS. 5.10 on "MD SELECTION"
(option)
The hold of the totalizer always
determines the interruption of the
batch. Exciting again the input 2
may have 2 results:
1) T< 1Sec: interrupted batch is
restarted
Closing
valve
2) T between 1 and 4 Sec:
interrupted batch is reset.
N.B.: it will be necessary to give a
new start pulse at input 2
(T< 1Sec) to start a new batch
Closing
valve
Holding the totalizer causes the current batch
to be stopped. The function "reset T2 enabled
on descent front" on input 1 resets the
totalizer of the current batch.
Therefore the presence of the consent or a
new pulse on the input 2 determines the start
Closing
of a new batch
valve
Necessary conditions for enabling the
function
POS. 5.6 (Block totalizer) ON
POS. 5.10 on "Batch" (option)
POS. 12.7 (consent mode) ON
POS. 5.2 (P+) ON
14
Necessary conditions for
enabling the function
POS. 5.6 (Block totalize) ON
POS. 6.1 OR 6.4 on "END
BATCH"
POS. 5.10 on "Batch" (option)
POS. 5.2 (P+) ON