(POS. 8.3) Display contrast set
Display visual contrast set. The contrast can change according to the room temperature. The set
values are from 0 to 15. The entered value has effect only when leaving the function itself.
Contrast can also be set from the visualization pages (pag. 17) by pushing key "ENTER" for at
least 8 seconds. In this way the contrast set will be visualized at release of the key.
(POS. 8.12-8.13) Conversion factor for flow rate totaliser
Set the value of conversion/currency for direct totaliser (positive). There are three fields for this
parameter, from left to right: 1) currency, 2 ) default/personalized currency, 3 ) conversion coefficient.
Set the cursor on the field to modify. There are two modes for selecting the currency:
Choose one of the 7 predetermined currencies (standard ISO 4217-REV81):
EUR = Eur ; USD = USA ; dollar CAD = Canadian dollar ; AUD = Australian dollar ;
GPB = English pound ; CHF = Swissfranc ; JPY = Japanese yen.
Choose three free characters (number or letter) . To change the characters, the cursor has to be
positioned on the symbol "/" (field N. 2)
(POS. 9.1) Date and time set
Date and time set. If the real time clock optional module is present, then the time setting is kept also
when the power supply is off, otherwise it is frozen till the power supply is back. For example, if the
power supply has been off for one hour, when switched on the instrument will be one hour late. The
calendar is valid till year 2091. N.B.: date and time are visualized on the display only if the data logger
is enabled (Pos 9.2).
(POS. 10.1) Transmitter "calibration"
Enables the calibration of the transmitter. Activate this function by pressing key "ENTER" during the
visualization of the function. Upon the request " EXECUTE?" press key "ENTER" for at least two
seconds to proceed. Press any other key to abort the operation.
(POS. 10.2) "Autotest" function enable/disable
Transmitter autotest function. This function stops the normal functions of the transmitter and performs
a complete test cycle on the measure input circuits and on the excitation generator. To activate this
function, select it then push key "ENTER": upon request "EXECUTE?" press key "ENTER" for at least
two seconds to start autotest, or any other key to abort the operation. The result of the test is shown on
the display. At the end of operation one of the visualization pages is dispalyed. This function is
automatically performed when switching on the device.
(POS. 10.3) Flow rate simulation
Flow rate simulation enabling. With this function it is possible to generate an internal signal that
simulates the flow rate, allowing the outputs and all the connected instrument to be tested. After
enabling it, the flow rate simulation can be:
set: by pushing key "RIGHT" for at least 1 second from one of the visualization pages
started: by pushing key "ENTER" after having set it
finished: by pushing key "RIGHT" for at least 1 second from any visualization page and then by
pushing key "ENTER" for at least 2 s.
N.B.: the enable of flow rate simulation disables the contrast regulation with a long press on key
"RIGHT" (Pos. 8.3).
MENU 8.DISPLAY
MENU 9.DATA LOGGER
MENU 10. DIAGNOSTIC
33
SE 56
[CONTRAST=X]
[EUR/dm³+ =X]
[
= dd/mm/yy hh:mm]
[CALIBRATION]
[SELF TEST]
[SIMULATION]