Cleaning The Container And The Pump; Voltage Examples; Cast Iron. 3.4% C, 0.29% Si, 0.6% Mn, 0.3% P; Duplex Steel - Struers Movipol-3 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cleaning the Container and the
Pump

Voltage Examples

Cast Iron. 3.4% C, 0.29%
Si, 0.6% Mn, 0.3% P

Duplex Steel

Commercial Pure Aluminium
99.5% Al
Movipol-3
Instruction Manual
The electrolyte container and the pump system must be cleaned with
water after use.
 Empty the container of electrolyte.
 Fill the container with water and start the pump by switching
O/Charge - l/Pump to bottom position to circulate water from the
electrolyte container through the pump system.
Due to graphite inclusions, electrolytic polishing is not ideal, but it is
satisfactory for "testing on the spot". The metallic structure develops
excellently and only the graphite appearance will be less successful.
Due to the softness of the graphite this may be helped by rubbing
the polished surface with a piece of wet cotton wool, perhaps with
AP-Alumina Suspension FF.
Pregrinding with Transpol
Electrolyte
Polishing voltage
Polishing current
Polishing time
Pregrinding with Transpol
Electrolyte
Polishing
Voltage
Current
Time
Etching
Voltage
Current
Time
Pregrinding with Transpol
Electrolyte
Polishing voltage
Polishing current
Polishing time
Up to grit 400
AC-2
40V
0.5A
15 sec
Up to grit 400
A-2
35V
0.7A
15 sec
8V
0.2A
12 sec
Up to grit 400
A-2
85V
0.3A
20 sec