6.6
Basic Functions
6.6.1 Display Mode
Input
Display (2-lines)
V4.1
INIT
Fuel flow
ENTER
ACT.
Vapor flow
ACT.
C-factor
ACT.
V/R-Ratio
ACT.
Corr. VR
ACT.
Vapor Vol
ACT.
Delay
ACT.
Warming up Pump
ACT.
Flow meter Calib.
ACT.
Pulser
ACT.
Nozzle
ACT.
64
Selection
Operator?
Evaluation
40,0
l/min
44,0
l/min
110
%
110
%
100
%
24,0
litre
Pump
2
sec
2
min
000
Generator
100
Imp/l
000
Remark
Selecting the operator mode
Fuel flow up to 51 l/min
Vapor flow up to 90 l/min
Correction factor from the
certificate of the system
Recovery rate
(air-/fuel volume)
Correct Recovery rate
(HC-vapor-/fuel volume)
Vapor volume
Time delay of the pump
Warming up time of the pump
before the self adaptation
Flow meter calibration factor
Value displayed on the flow
meter
Pulse rate
Nozzle (only with control
electronics Multiplex)
MKEN-1094 Version A and C