SHORT INSTRUCTIONS

Connections
Step 1:
Connect flow meter to nozzle
Step 2:
Connect hand held terminal to control electronics
and flow meter
Step 3:
Switch on the hand held terminal
(only necessary when battery powered)
Step 4:
Select the operator mode (Service)
Calibrating the vapor recovery system
Step 1:
Start the automatic self adaption
Testing
Step 1:
Start the test mode
Step 2:
Select the display of the recovery rate
Step 3:
Fuel flow simulation of 40 l/min. Wait for the recovery
rate to settle and check value
Step 4:
Change the simulated fuel flow
Step 5:
Wait for recovery rate to settle and check value
Step 6:
Return to display mode
Manual Setting of Parameters
Step 1:
Start manual setting
Step 2:
Select the value to be changed
Step 3:
Change value
Step 4:
Confirm the changed value
Step 5:
Finish manual setting
Switch off the device
Step 1:
Switch off the device (only necessary when battery
powered)
Operating Instructions No. 893 193
2 sec
ENTER
ENTER
AUTO
DATA
DATA
ENTER
ENTER