4 OPERATION

4.2 Operation Mode Display

The following variables are displayed in the operation mode:
45.6 L/ m
80529 L
6247 L.
4.3 Calibration Mode
Press
ENTER
The following variables can be set in the parameter definition menu:
LANGUAGE
UNIT
K-FACTOR
FILTER
TOTAL
END
Flow rate in the required engineering unit (see calibration menu)
The display switches to main totalizer after 10 s.
Main totalizer in the required engineering unit (see calibration
menu). Reset in the calibration menu.
Daily totalizer in the same engineering unit as the main totalizer.
A point behind the unit differentiates it from the main totalizer.
Reset by simultaneously pressing the
seconds.
select the flow display mode then
simultaneously for 5 seconds
Language selection between English, German, French, Italian....
Selection of engineering units to display flow rate and totalizer.
Input of K-factor according to chart or Teach-in function in order
to determine the specific K-factor.
Damping selection. There are ten different steps available.
Totalizer resetting.
Return to operation mode and storage of new parameters.
E-10-
FLOW TOTALIZER 8035
0......9
keys for 2