Total Open/Close Programming - Erreka TORO Manuel De L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

PROGRAMMING AND STARTUP KM1800
4

TOTAL OPEN/CLOSE PROGRAMMING

The programming of the gate open/close is done
using the transmitter, the ST1 mini-pushbutton or
the total key command (A.T.).
Start programming mode
Programme the operation
Finish the programming mode
The total opening and closing of the gate will be
memorised.
1 Place DIP1 and DIP2 in "OFF".
DL3 will remain off.
72
Installation Guide
Before making the programming, ensure there
is no person, animal or object in the radius of
action of the gate and the mechanism.
1 Close the gate by pressing PUL1.
2 Ensure that DIP7 is "OFF".
Operation times are memorised.
3 Place DIP1 and DIP2 in "ON"; DIP3, DIP4, DIP5 and
DIP6 in "OFF".
DL3
lights
programming mode.
G121T2
1 Start to open the gate: press ST1; the gate begins
to open.
2 Wait for the gate to come to a halt due to the
action of the opening limit switch.
3 Start closing the gate: press ST1; the gate begins
to close.
4 Wait for the gate to come to a halt due to the
action of the closing limit switch.
G95V2
up,
indicating
that
it
is
in

Publicité