Erreka TORO Manuel De L'installateur page 68

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTALLATION
Mount the limit switch magnets
64
Installation Guide
1 Secure the limit switch magnets (4) and (5) to the
magnet carrier plates (6) and (7) using the screws,
nuts and washers (8).
2 Secure the magnet carrier plates (6) and (7) to the
supports (9) using the screws and washers (10).
3 Move the gate manually to the opening position and
adjust the opening magnet (4).
In the gate open position, the magnet (4) must
be opposite the magnetic opening limit switch (Hall
effect sensor) (12).
The distance between the magnets and the
operator frame must be between 15 and 25 mm.
4 Move the gate manually to the closing position and
adjust the closing magnet (5).
In the gate closed position, the magnet (5) must
be opposite the magnetic closing limit switch (Hall
effect sensor) (13).
The distance between the magnets and the
operator frame must be between 15 and 25 mm.
5 Secure the supports (9) to the rack using the
pressure screws (11).
6 Lock the operator using the handle (2).

Publicité

Table des Matières
loading