PROGRAMMING AND STARTUP
4
TOTAL OPENING RUN PROGRAMMING
Programming the total opening run of the gate can be done using the ST1 mini-pushbutton, the wall key or the
transmitter.
Before making the programming, ensure there is no person, animal or object in the radius of action of
the gate and the mechanism.
Start programming mode
Programme opening
Programme closing
Finish the programming mode
1 Place DIP1 and DIP2 in "OFF".
DL3 will remain off.
The runs for the leaves both in opening and
closing will be memorised.
50
Installation Manual
1 Close the gate by pressing PUL1.
2 Place DIP1 and DIP2 in "ON" (operation
programming); DIP3, DIP4, DIP6 and DIP7 in "OFF".
DL3 comes on and remains static.
3 Installations with electrolock: place DIP5 in "ON"
(back pulse).
4 In operators with mechanical absorbers (such as
hydraulic motors), place DIP8 in "OFF" (electric soft
stop disabled).
1 Start opening: press ST1; the gate begins to open.
2 Start soft stop in opening (only if DIP8=ON):
press ST1 at the point chosen for the start of
deceleration (DA).
3 Finish opening: press ST1 in the gate open
position.
If the facility has an opening limit switch, it is not
necessary to press ST1.
1 Start closing: press ST1; the gate begins to open.
2 Start soft stop in close (only if DIP8=ON): press
ST1 at the point chosen for the start of deceleration
(DC).
3 Finish the closing: Press ST1 in the gate closed
position.
If the installation has a closing limit switch, it is
not necessary to press ST1.
The positions in which the leaf begins to slow
down, both in opening and in closing, are also
memorised (only if DIP8=ON).