PROGRAMMING AND STARTUP KM1800
1
CONNECTION TO THE POWER SUPPLY AND CHECKING OF TURNING DIRECTION
The correct operation of the operator and of the
complete system will only be achieved after
programming. However, prior to programming, it is
necessary to carry out the checks listed below.
Before carrying out any gate movement,
ensure there is no person or object in the radius
of action of the gate and the operation
mechanisms.
2
CONTROLS AND COMMANDS
1 Connect the control panel power supply.
2 Check the turning direction of the operator using
the mini-pushbuttons PUL1 (close) and PUL2 (open).
If the turning direction of the operator is not correct,
interchange the connection cables (black cables) in their
corresponding connector (see "Electrical connections"
on page 65).
SW1
Main switch
SW2
Programming DIPs
ST1
Total operation mini-pushbutton
ST2
Pedestrian operation mini-pushbutton
PUL1
Close mini-pushbutton
PUL2
Open mini-pushbutton
T.LG
Garage light time regulation (3-90 seconds)
T.E
Standby time regulation (0-90 seconds)
(only functional in automatic mode)
P.M.
Torque adjustment (set to the maximum)
English
TORO operator for sliding gates
69