Stiebel Eltron DHE Connect 18 Utilisation Et Installation page 97

Masquer les pouces Voir aussi pour DHE Connect 18:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 113
INSTALLATION
Alternative installation methods
Note
Use the cover guides with sealing lips if the connection
pipes are slightly offset. In this case, the back panel
guides are not fitted.
14.9 Lower back panel section installation with
threaded fittings on finished walls
3
1
1 Lower back panel section
2 Connection piece in the standard delivery
3 Screw
If using threaded fittings on finished walls, the lower back panel
section can also be installed after fitting the taps. To do this, carry
out the following steps:
f Cut open the lower back panel section.
f
f Fit the lower back panel section by bending it out at the sides
f
and guiding it over the pipes.
www.stiebel-eltron.com 
f Insert the connection pieces into the lower back panel sec-
f
tion from behind.
f Click the lower back panel section into place.
f
f Secure the lower back panel section with a screw.
f
14.10 Wall mounting bracket when replacing an
An existing STIEBEL ELTRON wall mounting bracket may be used
when replacing appliances (except the DHF instantaneous water
2
heater), as long as the fixing screw is in the lower right position.
Replacing a DHF instantaneous water heater
f Reposition the fixing screw on the wall mounting bracket (the
f
fixing screw has a self-tapping thread).
f Rotate the wall mounting bracket 180° and mount it on the
f
wall (the DHF logo is then turned towards you).
appliance
DHE Connect | DHE Touch |
97