INSTALLATION
Alternative installation methods
Material losses
!
Connect the phase that switches the load shedding relay
to the indicated terminal of the mains terminal in the
appliance (see chapter "Specification / Wiring diagram").
14.6 Water installation on finished walls
Note
This type of connection changes the IP rating of the ap-
pliance.
f Change the type plate. Cross out "IP 25" and mark
f
the box "IP 24". Use a ballpoint pen to do this.
24
18 Nm
www.stiebel-eltron.com 
f Fit water plugs with gaskets to seal the concealed connec-
f
tions. All taps obtained as accessories are supplied with
plugs and gaskets as standard. For pressure taps other than
those recommended by us, plugs and gaskets can be ordered
as accessories.
f Fit a suitable pressure tap.
f
f Push the lower back panel section under the connection
f
pipes of the tap and push it into the back panel.
f Secure the connection pipes to the tee and the 3-way ball
f
shut-off valve.
19
5 Nm
1 Tab
Note
You can break off the pipe fitting tabs on the lower back
panel section if required.
1
DHE Connect | DHE Touch |