Configuration Of The "Zoning" Option - SORHEA MAXIRIS 3000 Notice D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SORHEA
 Intrusion alarm settings

Configuration of the "Zoning" option

8.3
Activation of the "Zoning" option
Configure the "Zoning" option of the Tx and Rx columns.
Click the "Alarms" Tab.
In "Intrusion Alarm", select "Zoning" to activate the option.
Activation of the
"Zoning" option
The "Zoning" option can only be activated on column equipped with 4 up to 10 cells.
Parameters
Single detection
Dual detection
Triple detection
Dual transmission
ON / OFF
Response time
[40ms, 500ms] Interruption time of beams for
Time-delayed mono detection
Bottom beam
ON / OFF
[40ms, 5s]
Other beams
ON / OFF
[40ms, 5s]
Zoning
ON / OFF
- 71 -
MAXIRIS 3000 / 3100
Values
Mode
Intrusion alarm when 1 beam is cut
/
Intrusion alarm when at least 2
/
adjacent beams are cut
Intrusion alarm when at least 3
/
adjacent beams are cut
To activate on RX and TX columns.
Not available on zoning mode
column.
intrusion alarm
Independent management of
bottom beam
Independent management of other
beams
Enable option "Zoning" on a column
if continuous Beams allocation.
To activate on RX and TX columns.
Notes

Hide quick links:

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Maxiris 3100

Table des Matières