SORHEA
4.2
Installation of MAXIRIS 3100 columns
Wall fastening: Please refer to the manual given with the wall brackets
Detail of sealing base plate
Fasten the 4 anchor bolts into a concrete block using the template (provided) to ensure proper
vertical emplacement of the bolts.
Position the floor socket sealing so that it is properly oriented with the beams.
The fastening plate of the package serves as a template for the sealing kit.
250 mm / 9.8 in
200 mm / 7.9 in
Mounting the column on the floor socket
4 anchors
stalks
M16x250
hole : 50x130 mm
125 mm
/ 4.9 in
1
Mount the guides.
Do not tighten the
screws.
Beam utilization
zone: 90°
/ 1.97x5.1 in
- 50 -
MAXIRIS 3000 / 3100
Slide the column between
the 2 pillars of the floor
2
socket.
Leave a space between
the bottom of the column
and the template of the
floor socket to allow the
wires to go through.
Tighten the fastening
screws of the guides to
keep the column stable.