8.3 Configuration of mono-detection : ATF

Command :
Nota : the mono-detection is select only in COLIRIS II 50/100.

8.4 Configuration of response time for mono-detection : ATT

Command :

8.5 Configuration of heater instruction : ATC

Command :

8.6 Read control unit settings : ATL

Display control unit settings:
-
Type of column
-
Status of mono-detection on the bottom cell
Heating instruction
-
-
Response time for mono detection on the bottom cell
-
Version of included software
Command examples :
Activation of mono-
detection on the
bottom cell
Configuration of
heater instruction
at 25° C
Response time for
mono detection on the
bottom cell at 1.5 s.
Read control
unit settings
ATF0: Deactivation of mono-detection of the bottom cell (by default)
ATF1: Activation of mono-detection on the bottom cell
ATTxxxx (by default 1500 ms)
xxxx → 4 numbers representing the response time of the mono-detection
on the bottom cell (in ms).
Adjustable in increments of 100 ms to 1000 to 5000
(100 ms at 5 s).
ATCxx
(by default 20°C)
xx → 2 numbers representing the temperature that triggers heating (in °C).
Adjustable from 00 to 90
Validated command
- 38 -
Type of column : COLIRIS II 100m
Status of mono-detection : Activated
Heater instruction set at 25° C
Response time for mono detection on the
bottom cell set at 1500 ms
Version of on-board software
COLIRIS II 50/100/200