6.2
Optimizing alignment
Alignment push
button "Select"
Check that the green LED "Sync." is constantly lit.
The alignment consists in finding the position that gives the maximum signal.
Optimize the alignment of the TX column by following the procedure described in the table,
and do the same on the RX column.
For a maximum range of 100m / 328 ft, try to get the maximum of LEDS ON constantly
without blinking.
If it is too difficult to have all the LEDS ON constantly without blinking, try to have the
buzzer sounding a continuous beep with the red LED ON constantly without blinking and at
least the green LED blinking.
For a range greater than 100 m / 328 ft, try to get the red LED ON constantly without
blinking.
Signal
Signal max.
- 59 -
Red LED "Alarm"
Green LED "Sync."
Orange LED "Disq."
Position
MAXIRIS 3000 / 3100