Wiring; Single Direction - SORHEA MAXIRIS 3000 Notice D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SORHEA
5

WIRING

The terminal board wiring is the same whatever the type of the column. (Tx, Rx)
5.1

Single direction

White direction
ON
Terminal board POWER
Ground
Ground + 230V AC / 110V AC
N (+)
L (-)
*
Position of switches for wiring the tamper contact to the removal terminal blocks:
Position of switches
ON
Switches up
ON
Switches down
N° of terminal Description
Tamper contact available on terminals 1 and 2
Tamper contact available the bus
(MAXIBUS III network)
- 53 -
1
Tamper *
2
Tamper *
3
+ Auxiliary input
4
- Auxiliary input
5
Not in use
6
Not in use
7
Not in use
8
Not in use
9
Intrusion relay white NO
10
Intrusion relay white COM
11
Disqualification relay white NO
12
Disqualification relay white COM
Ground
S1 +
Not in use
S1 -
Not in use
S2 +
+ Synchronization white
S2 -
- Synchronization white
A
BUS
B
BUS
A
BUS
B
BUS
Description
MAXIRIS 3000 / 3100

Hide quick links:

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Maxiris 3100