SORHEA
5.3
Double direction, double face mounting for column MAXIRIS 3100 only
1. Wiring the terminal block (white direction)
White direction
ON
Terminal board POWER
Ground
Ground + 230V AC / 110V AC
N (+)
L (-)
*
Position of switches for wiring the tamper contact to the removable terminal blocks:
Position of switches
ON
Switches up
ON
Switches down
2. Wiring the interconnection board (yellow direction):
Tamper contact available on terminals 1 and 2
Tamper contact available the bus
(MAXIBUS III network)
Yellow direction
N° of terminal Description
1
Tamper*
2
Tamper*
3
+ Auxiliary input
4
- Auxiliary input
5
Not in use
6
Not in use
7
Not in use
8
Not in use
9
Intrusion relay white NO
10
Intrusion relay white CO
11
Disqualification relay white NO
12
Disqualification relay white CO
Ground shield
S1 +
Not in use
S1 -
Not in use
S2 +
+ Synchronization white
S2 -
- Synchronization white
A
BUS
B
BUS
A
BUS
B
BUS
Description
N° of terminal
Ground shield
S1 +
+ Synchronization yellow
S1 -
- Synchronization yellow
INT
Intrusion relay yellow NO
INT
Intrusion relay yellow COM
DISC
Disqualification relay yellow NO
DISC
Disqualification relay yellow COM
- 55 -
MAXIRIS 3000 / 3100
Description