PERIODIC MAINTENANCE
To ensure proper performance over time, minimum maintenance should be performed:
- Clean the cover of each component at least once a year, (or more often depending on
exposure to foreign elements and grime).
11
MAINTENANCE
VISUAL FAULTS
Green LED "Sync." blinking
Red LED "Alarm" blinking.
Orange LED "Disq."
permanently lit
Red LED "Alarm"
permanently lit
Orange LED "Disq."
permanently lit.
LEDs are blinking one after
the other.
Tamper signal remains ON
in the web server
(network use)
PROBABLE CAUSES
1. Synchronization inverted,
cut or short circuit
2. Associated column without
power
3. Associated columns error
Type
4. Mode zoning is not set in
the same way on each
block of the area
1. 12V and/or 230V fault.
2. Alarm anti-climbing cap
3. Alarm auxiliary input.
1. Significant drop in I.R.
signal level due to
environment
1. Power or battery too low
for the column to work
correctly
1. Control board not
configured
2. Terminal board not
configured.
(check the after sale manual)
Bad switch position on the
terminal block
- 79 -
MAXIRIS 3000 / 3100
SOLUTIONS
1. Check the wiring of the
synchronization.
2. Check column power
3. cf. §5.4 Wiring the
synchronization between the
columns
4. Check that the zoning mode is
enabled / disabled on each
block of the zone
1. Check power status
2. Check wiring and settings
1. Check the alignment.
2. Make sure a beam is not
partially hidden by vegetation
or a dirty cover
1. Check power status
1. Configuration from the terminal
board.
2. Configuration from control
board
(check the after sale manual)
Turn the switches down (see §5).