SORHEA
By default, anti-climbing cap is enabled. (box "Activated" below "Anti-climbing device"
checked).
Auxiliary input unused: auxiliary input not managed
Auxiliary input sets as Alarm input: permits to integer an external contact in the column
Principle of the auxiliary input polarization:
3
+ Auxiliary
4
- Auxiliary
Auxiliary input sets as History validation: permits to stop the memorization of the events in
the column memory of the white and/or yellow zones.
Select the zones managed by the external contact in the right side.
Events stopped:
Intrusion
Disqualification / end disqualification
Receiver auxiliary alarm
Transmitter auxiliary alarm
Receiver anti-climbing device alarm / back to receiver anti-climbing device alarm
Transmitter anti-climbing device alarm / back to transmitter anti-climbing device
alarm
Defect of mains transmitter / back to mains transmitter
Defect of mains receiver / back to mains receiver
Intrusion alarm zone 1, intrusion alarm zone 2, intrusion alarm zone 3
Disqualification of cross beams, back to cross beam
7.4.6 Clock settings
Updating the direction with the PC time by clicking on "Send".
External contact
+
External
12V DC power supply
-
Time of PC
Set the column clock
- 68 -