Default Configuration - SORHEA MAXIRIS 3000 Notice D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SORHEA
9

DEFAULT CONFIGURATION

Title
IP address
Subnet mask
Connection login
Connection password
"admin"
Connection login
Connection password
"user"
Name of the white zone
Name of the yellow zone
ModBus 485
Heater setpoint
Detection mode
Mono detection bottom
beam
Time-delayed mono
detection on other beams
Synchronization type
Dual transmission
Minimum number of
disqualified beams
Response time of
disqualification alarm
Manual ejection of beams
Value
192.168.105.202
255.255.255.0
"admin"
4 spaces) Column parameters, read-and-write
(
"user"
"0000"
"Zone1"
"Zone2"
ON
Address = 129
22°C / 71,6 °F
Dual detection
OFF
OFF
1
OFF
1
1 minute
OFF
- 78 -
Notes
To be entered in the browser URL
Check compatibility with the host's
network compatibility
Connection parameter in ASCII (match
case)
access
Connection parameter in ASCII (match
case)
Column parameters, read only access
Case sensitive for 15 characters
(accents and special characters not
recognized)
Case sensitive for 15 characters
(accents and special characters not
recognized)
To connect the barrier to the bus network
0° to 100°C / 32°F to 212°F
Intrusion alarm by interruption of at least
two adjacent beams
Intrusion alarm by interruption of bottom
beam for a preset period (time-delayed
mono detection lower beam, default :
1.5s)
Intrusion alarm when one beam is cut,
regardless of the detection mode, for a
predefined period (beam exception delay)
Synchronization type of the column
For extreme weather conditions (thick
fog)
From 1 to the number of beams of the
barrier
From 1 to 4 minutes
Possibility of ejecting from 1 to all beams
of the barrier
MAXIRIS 3000 / 3100