Roland Edirol UR-80 Mode D'emploi page 380

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MIDI implementation
System common message
On the UR-80 you can assign the following system common messages to LED mode
and receive them.
MTC quarter frame
Status
2nd byte
F1H
mmH
mm = Message type/value
Song position pointer
Status
2nd byte
F2H
mmH
mm, ll = Song position:
Song select
Status
2nd byte
F3H
mmH
mm = Song number:
Tune request
Status
F6H
System realtime message
* In addition to Active Sensing messages (which are always received), the UR-80
can receive the following System Realtime messages that you assign in LED
mode.
Timing clock
Status
F8H
Start
Status
FAH
Continue
Status
FBH
Stop
Status
FCH
Active sensing
Status
FEH
* When Active Sensing is received, the UR-80 will begin monitoring the interval
between all subsequent messages. If a gap of greater than 420 ms between
messages occurs while monitoring is being performed, the UR-80 will transmit
All Sound Off and Reset All Controller messages to all ports.
System reset
Status
FFH
380
3rd byte
llH
00 00H - 7F 7FH (0-16383)
00 00H - 7F 7FH (0-16383)
System exclusive messages
Universal non-realtime system exclusive message
Identity request message
Status
Data byte
F0H
7EH, dev, 06H, 01H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (Universal non-realtime system exclusive message)
dev
Device ID (10 or 7FH (Broadcast))
06H
Sub ID #1 (General Information)
01H
Sub ID #2 (Identity Request)
F7H
EOX (End of Exclusive)
Data transmission
The UR-80 can use Bulk Dump (p. 383) to transmit the data of its internal memory
sets (p. 349).
Data Set 1DT1 (12H)
This message transmits the actual data, and is used to load the data into the device.
Status
Data byte
F0H
41H, 10H, 00H, 68H, 12H,
aaH, ddH, ...eeH, sum
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
10H
Device ID (For the UR-80, fixed at 10H)
00H
Model ID #1 (UR-80)
68H
Model ID #2 (UR-80)
12H
Command ID (RQ1)
aaH
Address
ddH
Data
:
:
:
eeH
Data
sum
Checksum
F7H
EOX (End of Exclusive)
* The amount of data that can be transmitted at once is fixed for each type of data.
Data that does not have the specified starting address and data size will not be
received. Refer to the explanation in 3. Bulk Dump (p. 383).
* There must be an interval of at least 40 ms between each exclusive message that
is sent.
Status
F7H
Status
F7H

Publicité

Table des Matières
loading

Table des Matières