Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
Power source:
Mains voltage (50Hz-60Hz)
Fuse
Mains current, effective
Power, (100%)
Power, max
Open circuit power
Efficiency
Permitted load:
100% duty cycle (40°C ambient temp)
60% duty cycle (40°C ambient temp)
40% duty cycle (40°C ambient temp)
35% duty cycle (40°C ambient temp)
100% duty cycle (20°C ambient temp)
60% duty cycle (20°C ambient temp)
Open circuit voltage
Current range
1
Application class
2
Protection class (IEC 529)
Standards
Dimensions (hxwxl)
Weight
Cut quality
Cut max.
Autotransformer:
Mains voltage (50Hz-60Hz)
Mains current, effective
Mains current, max.
Weight, incl. autotransformer
Dispose of the product according to
local standards and regulations.
www.migatronic.com/goto/weee
S
1
The machine meets the standards which are demanded of machines working in areas where there is an increased risk of electric shock
2
Equipment marked IP23 is designed for indoor and outdoor applications

TECHNICAL DATA

ZETA 60
ZETA 100
3x400 V ±15%
3 x 400 V ±15%
10 A
20 A
6.8 A
19.1 A
4.7 kVA
13.2 kVA
7.4 kVA
29.9 kVA
< 35 W
< 35 W
0.9
0.8
Cutting
40 A / 96 V
75 A / 110 V
50 A / 100 V
85 A / 114 V
60 A / 104 V
100 A / 120 V
-
-
45 A / 98 V
-
55 A / 102 V
-
241 V
248 V
20-60 A
20-100 A
S
S
IP 23
IP 23
EN/IEC60974-1
EN/IEC60974-10 (Class A)
360x220x570 mm
405x345x675 mm
27 kg
36 kg (6 m)/39 kg (15 m)
12 mm
<25 mm
18 mm
<35 mm
ZETA 100
3x230-500 V ±15%
46.8 A (230 V)
26.9 A (400 V)
24.5 A (440 V)
21.5 A (500 V)
33.2 A (230 V)
19.1 A (400 V)
17.4 A (440 V)
15.3 A (500 V)
112 kg
12
Gouging
75 A / 130 V
85 A / 134 V
-
100 A / 130 V
-
-

Publicité