26. Correction of Malfunctions

Problem
No coating material
emerges from the
nozzle
Coating material
drips from the
nozzle
Atomisation too
coarse
Spray jet pulsates
Coating material
causes "paint tears"
Too much fog of
coating material
(Overspray)
Paint in the
ventilating hose
Cause
Nozzle clogged
Material volume setting turned
too far to the left
Suction tube clogged
Suction tube loose
No pressure build-up in container
Ventilating bore (Fig. 25, 1)
clogged
Coating material assembly at air
cap, nozzle or needle
Nozzle loose
Nozzle seal is missing or worn
Nozzle worn
Material volume too large
Material volume adjusting screw
turned too far to the right
Nozzle contaminated
Coating material too thick
Air filter heavily soiled
Too little pressure build-up in
container
Coating material in container
running out
Nozzle seal is missing or worn
Air filter heavily soiled
Too much coating material
applied.
Distance to the object too large
Too much coating material
applied
Diaphragm soiled
Diaphragm defective
Remedy
➞ Clean
➞ Turn to the right
➞ Clean
➞ Insert
➞ Tighten container
➞ Clean
➞ Clean
➞ Tighten
➞ Insert an intact nozzle
seal
➞ Change
➞ Turn material volume
adjusting screw to the
left
➞ Clean
➞ Dilute
➞ Change
➞ Tighten container
➞ Refill
➞ Insert an intact nozzle
seal
➞ Change
➞ Turn material volume
adjusting screw to the
left
➞ Reduce distance
➞ Turn material volume
adjusting screw to the
left
➞ Clean the diaphragm
➞ Replace the diaphragm
GB