GB
Before loosening the screw connections always allow the unit cool down for at
least 2 minutes. Caution! Risk of scalding!
Heated water can leak from the steam plate during the heating-up phase. Hot water
can drip during overhead work.
Descaling
Regular descaling is key to your steamer functioning properly. Depending on
i
water hardness, descale the steam wallpaper remover after 10 – 15 fills.
Devices which are defective due to a lack of descaling are excluded from the
warranty!
•
Use a standard descaling agent (e.g. household vinegar).
Observe the manufacturer's instructions for use!
•
Mix the vinegar with water (ratio 1:1).
•
Fill the steam wallpaper remover with around 2.5 litres of descaling solution.
•
Switch the steam wallpaper remover on for around 10 minutes.
•
Switch the steam wallpaper remover off again and disconnect the mains plug.
•
Leave the descaling solution to work for around 30 minutes..
•
Then fully empty the steam wallpaper remover.
•
Thoroughly rinse the device two to three times with clear water to remove all descaling solution
residue.
Storage
Store emptied, upright and dry.
Technical data
Power source:
Steaming time:
Reservoir capacity:
Weight of the steam bar:
Correction of Malfunctions
Problem
The steam
wallpaper remover
is not working
6
230 -240 V ~
max. 80 min.
4.0 l
145g/190g/240g
Cause
•
Heating element covered in limescale
•
Too little water in tank
•
Device at an angle, heating element is not
in the water
Power consumption:
Steaming power:
Hose length:
Weight of the steam plate:
Remedy
➞
➞
➞
W 16
2000 W
50 g/min.
3.5 m
220 g
Descale
Fill with more water
Move device into
horizontal position