Technical Data; Correction Of Malfunctions - WAGNER W 16 Mode D'emploi

Masquer les pouces Voir aussi pour W 16:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
Before loosening the screw connections always allow the unit cool down for at
least 2 minutes. Caution! Risk of scalding!
Heated water can leak from the steam plate during the heating-up phase. Hot water
can drip during overhead work.
Descaling
Regular descaling is key to your steamer functioning properly. Depending on
i
water hardness, descale the steam wallpaper remover after 10 – 15 fills.
Devices which are defective due to a lack of descaling are excluded from the
warranty!
Use a standard descaling agent (e.g. household vinegar).
Observe the manufacturer's instructions for use!
Mix the vinegar with water (ratio 1:1).
Fill the steam wallpaper remover with around 2.5 litres of descaling solution.
Switch the steam wallpaper remover on for around 10 minutes.
Switch the steam wallpaper remover off again and disconnect the mains plug.
Leave the descaling solution to work for around 30 minutes..
Then fully empty the steam wallpaper remover.
Thoroughly rinse the device two to three times with clear water to remove all descaling solution
residue.
Storage
Store emptied, upright and dry.

Technical data

Power source:
Steaming time:
Reservoir capacity:
Weight of the steam bar:

Correction of Malfunctions

Problem
The steam
wallpaper remover
is not working
6
230 -240 V ~
max. 80 min.
4.0 l
145g/190g/240g
Cause
Heating element covered in limescale
Too little water in tank
Device at an angle, heating element is not
in the water
Power consumption:
Steaming power:
Hose length:
Weight of the steam plate:
Remedy
W 16
2000 W
50 g/min.
3.5 m
220 g
Descale
Fill with more water
Move device into
horizontal position

Publicité

Table des Matières
loading