Control function i:
→
Connect the control medium to the
actuator (see "Fig. 17: Pneumatic Connection")
Pressure on connection 1 opens the valve.
Pressure on connection 2 closes the valve.
Air discharge connection
CF A, CF B
Pilot air port CF I
Pilot air port
CF A, CF B, CF I
Fig. 17:
Pneumatic Connection
Control air hose:
6/4 mm or 1/4" control air hoses can be used.
Optionally a pilot air port is possible via a G 1/8 thread.
Type 2100
Installation
pilot air port 1 and 2 of the
2
1
8.5.
removal
DAnger!
risk of injury from discharge of medium and pressure!
It is dangerous to remove a device which is under pressure due to
the sudden release of pressure or discharge of medium.
•
Before removing a device, switch off the pressure and vent the
lines.
procedure:
→
Loosen the pneumatic connection.
→
Remove the device.
english
27