8.
insTallaTiOn
8.1.
safety instructions
DAnger!
risk of injury from high pressure!
•
Before loosening the lines and valves, turn off the pressure and
vent the lines.
wArning!
risk of injury from improper installation!
•
Installation may be carried out by authorized technicians only
and with the appropriate tools!
risk of injury from unintentional activation of the system and
an uncontrolled restart!
•
Secure system from unintentional activation.
•
Following installation, ensure a controlled restart.
wArning!
For control function i – danger if pilot pressure fails!
For control function I control and resetting occur pneumatically. If
the pressure fails, no defined position is reached.
•
To ensure a controlled restart, first pressurize the device with
pilot pressure, then switch on the medium.
22
english
Type 2100
Installation
8.2.
Before installation
•
The angle seat valve can be installed in any installation position,
preferably with the actuator face up.
•
Before connecting the valve, ensure the lines are flush.
•
Observe direction of flow (see type label).
8.2.1.
preparatory work
→
Clean pipelines (sealing material, swarf, etc.).
devices with welded body
Remove the actuator from the valve body:
→
Clamp the valve body in a holding device.
noTiCe!
damage to the seat seal or the seat contour!
•
When removing the actuator, ensure that the valve is in open
position.
→
Control function A
pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.
→
Using a suitable open-end wrench,
pipe.
→
Unscrew the actuator from the valve body.
place the wrench flat on the