8.3.2.
install actuator (Welded Body)
Fig. 14:
Graphite seal
→
Check the graphite seal and if required, replace it.
wArning!
danger if incorrect lubricants used!
Unsuitable lubricant may contaminate the medium. In oxygen
applications there is a risk of an explosion!
•
In specific applications, e.g. oxygen or analysis applications,
use appropriately authorised lubricants only.
→
Grease nipple thread before re-installing the actuator (e.g. with
Klüber paste UH1 96-402 from Klüber).
noTiCe!
damage to the seat seal or the seat contour!
•
When installing the actuator, ensure that the valve is in open
position.
24
Graphite seal
english
Type 2100
Installation
→
Control function A
pressurize the pilot air port 1 with com-
pressed air (5 bar): valve opens.
→
Screw actuator into the valve body.
Observe tightening torque (see „Tab. 5: Tightening torques of
valve body / nipples").
Air discharge connection
2
CF A, CF B
Pilot air port
CF I
1
Pilot air port
CF A, CF B, CF I
Fig. 15:
Connections
tightening torques of valve body / nipples
dn
tightening torque [nm]
13/15
45 ±3
20
50 ±3
25
60 ±3
32
65 ±3
40
50
70 ±3
65
Tab. 5:
Tightening torques of valve body / nipples