10.3.1. Removal procedure
If the actuator has to be removed for maintenance, first
remove the actuator from the fitting.
NOTE!
Before removal, ensure that:
• The actuator is not under pressure and that the springs are in
the end position,
• The connections 2 and 4 are not under pressure and are free
from any accessories or devices.
If the actuator is single-acting, ensure that:
• The actuator is in the home position and that the pistons are all
the way in.
Removing position indicator and graduated ring (Pos. 19, 19.0,
19.1):
19
Fig. 7:
Removing position indicator
18
39
english
Type 2051
Maintenance,Troubleshooting
Remove screw (Pos. 39) if fitted,
Remove position indicator (Pos. 19 or 19.1) from shaft end. If
required, use a screwdriver as a lever,
Remove graduated ring (Pos. 19.0) from housing. If required, use
a screwdriver as a lever.
Removing the adjusting screws (Pos. 02):
Fig. 8:
Removing the adjusting screws
Remove adjusting screws together with nuts (Pos. 04) and washers
(Pos. 03),
Remove seals (Pos. 11) from the adjusting screws and dispose of
(if all sealing rings are replaced).