Device Versions; Designated Application Area - Burkert 2100 Manuel D'utilisation

Masquer les pouces Voir aussi pour 2100:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.2.1.
Options
Control unit
Different versions of the control units are available depending on
the requirement.
Stroke limitation
Limit of the maximum open position/flow rate by means of
adjusting screw.
Feedback indicator
The device features mechanical limit switches or inductive prox-
imity switches.
5.2.2.
device versions
The angle seat valve is available for the following actuator sizes:
ø 50 mm, ø 70 mm, ø 90 mm, ø 130 mm .
5.2.3.
restrictions
wArning!
risk of injury from water hammer.
A water hammer could crack the lines and device.
Due to the risk of water hammer, valves with a flow direction
above the seat must not be used for liquid media.
Consider the type of flow direction and the type of medium for
operation of the device.
10
english
Type 2100
Product description
5.3.
designated application area
Observe the maximum pressure range according to the
type label!
Neutral gases and liquids up to 16 bar.
Steam up to 10 bar / 180 °C.
Aggressive media.
5.3.1.
application areas
e.g.
Plant construction
Food processing
Chemical engineering
Sterilizer construction

Publicité