Instruction for use and maintenance
Spiral mixer with removable bowl SPI 160-300 A HYBRID
PROBLEM
The display shows the message
"ACTIVE EMERGENCY PUSH
BUTTON".
If the display shows "VERIFY
THE MAGNETOTHERMAL IN-
TERVENTION".
If the display shows "HEAD
OUT OF POSITION - LOWER
THE HEAD".
If the display shows "HEAD
OUT OF POSITION".
If the display shows "VERIFY
SQ1-SQ2 END STROKE".
If the display shows "VERIFY
THE TEMPERATURE PROBE".
SQ1
46
POSSIBLE CAUSE
Emergency button pressed.
When a circuit breaker trips
inside the electrical panel.
When the head is completely
closed and the power supply
is interrupted.
When pressing START button
in an intermediate position of
the head.
Working time at "0".
Pressing START when the trol-
ley is not completely hooked.
When the temperature probe
is present and the mixture
exceeds the set temperature
set.
Figure n°38
SQ2
POSSIBLE SOLUTION
Check and turn to the right to
release the button.
Check which breaker is tripped
and reset it.
Move up the head a few inches
and then proceed with the de-
scent.
Complete closure of the head
before pressing start.
Verify that the time is not at
"0" (excluding program H)
Press the related buttons and
move down the head.
Complete the coupling of the
trolley and the closure of the
head before press START.
Check the temperature of the
dough and the set value. Check
the probe.
Figure n°39