III
– Location of "S" and "+" keys
1) These two keys are located on the back of the clock:
– Right side: when viewed from the back
– Left side: when viewed from the front (when being handled)
2) The "S" key is above the "+" key.
3) When pressed, an LED lights up to indicate the selected key.
Example (Style 7D) showing the two keys pressed simultaneously:
IV
– Styles 5S & 10S – Timer mode
1) The timer keypad operates in count or countdown modes.
It has the following functions: start, stop, split time, closure of a dry contact when the count or
countdown ends (stops at a pre-programmed time).
The timer keypad can control up to ten Style 5S or Style 10S clocks.
The electronic board for Style 5S and Style 10S clocks is fitted with a connector strip (j).
2) Connect the timer keypad to the strip (j) using a 4-core cable (T-, T+, 0V and 15V) for the
first clock.
Wiring example with three Style 5S clocks:
Yellow
15V
Green
0V
White
T+
Brown
T-
20 m
max.
Double sided case:
- To display the timer on both sides connect the keypad on the master clock.
- To display the timer on only one side and the local time on the other side, connect the
keypad on the slave clock.
3) To link several Style 5S or Style 10S clocks to a single timer keypad, connect the T- and T+
terminals together using a 2-core cable (twin telephone cable). The first clock remains connected to
the timer keypad via a 4-core cable.
4) For more information, please refer to the timer keypad instructions.
8/10 cable, twin pairs (unshielded)
EN
11