VI - PRINCIPLE OF TIME SETTING

6.1 NTP receivers

1.
When they are first switched on, the time is initialized at 00:00:00 on 01/01/2000.
The clock attempts to synchronise on switching on, after each manual time change, or
after a reset or reconfiguration of the clock; as soon as three consecutive coherent
messages have been received, it adjusts its time base.
The time displayed takes into account the time differences chosen in the time menu (time
differences and seasonal changes).
If there is no NTP message for more than one hour, the clock pictogram flashes every
second and the clock continues autonomously.
In NTP mode, if the synchronisation is not correct after 24 hours, the clock pictogram will
flash every 5 seconds; the display goes black with the two fixed dots.
In NTPI mode, if the synchronisation is not correct after 24 hours, the clock continues to
function on its internal quartz crystal with the two fixed dots.
Caution: if a time change is made on the master clock after synchronisation, the
correction will be made only after reception of three coherent messages.

6.2 Annex for time difference

Choose the reference country for the summer/winter time changes, as well as the time
difference, according to the city in which you wish to display the local time.
CITY
LOS ANGELES
MEXICO
CHICAGO
NEW YORK, TORONTO
BUENOS AIRES
RIO DE JANEIRO
LONDON
PARIS (*)
HELSINKI, ATHENS
JOHANNESBURG
MOSCOW
SINGAPORE (**)
TOKYO, SÉOUL
SYDNEY
WELLINGTON
PARAGUAY
TEHERAN
BOMBAY
(*) Paris and the following cities: Frankfurt, Madrid, Stockholm, Oslo, Zurich, Milan,
Amsterdam, etc.
(**) SINGAPORE, and the following cities: Taipei, Bangkok, Hong-Kong, Kuala Lumpur,
Beijing, etc.
28
Zone
Reference zone
USAP
United States / Canada
USAC
United States / Canada
USAC
United States / Canada
USAE
United States / Canada
GMT
No Change
PRG
Programmable Mode
EU_1
Europe
EUR
Europe
EAST
Europe
GMT
No Change
EAST
Europe
GMT
No Change
GMT
No Change
AUS
Programmable Mode
PRG
Programmable Mode
PRG
Fixed Date ( every year)
PRG
Fixed Date ( every year)
GMT
No Change
Time difference/GMT
-08
-06
-06
-05
-03
-03
00
+01
+02
+02
+03
+08
+09
+10
+12
-04
+3.30
+5.30