III - Installation
Choose a location where the clock is to be installed, preferably away from sources of electrical
interference, such as transformers. The data network must be PoE (802.3af, class 3): if not, use a
PoE injector to power the clock, for example ref. 927223.
3.1 Installation and connection of the Single Face clock (SF)
a. Turn the clock upside down on a table.
■ Unscrew the anti-theft locking screw.
■ Push the wall holder opposite the two arrows to unclip it.
■ Remove the wall bracket on the back of the clock.
b. Connect the Ethernet network on the RJ45 connector.
■ Ethernet cable category: 4, 5 or 6 (buildings). In the latter case, use a female wall
connector with a small flexible male/male RJ45 cable.
The clock synchronisation mode will have to be selected in the Technician Menu (see pages 46
and 47), particularly the Multicast address which must be the same as that of the server (by
default 239.192.54.01). Find the MAC address which will be useful during the detection of the
clock on the software Bodet Detect to reappoint it.
Setting of the table bracket (if supplied)
(in the 2 notches of the wall bracket).
32
143
100
252
Reset
Sel.
Anti-theft locking
Reset
SELECT
∞
C
Anti-theft locking screw
screw