III
–
Default configuration
To restore factory settings, press the red button on the electronic board until the clock turns black. Open the clock to
access this button (see Installation).
Location of button on the electronic board (e.g. a Style 5 clock):
The full factory configuration is as follows:
• IP configuration by DHCP (DHCP: ON)
• Time zone: EUR
• Synchronisation: Multicast
• Synchronisation address: 239.192.54.1
These four parameters are displayed on the electronic board.
• Clock name: BODET-@MAC
• Pool period for unicast synchronisation: 15 mins.
• SNMP disabled
• Trap type: V2C
• Temperature alarm threshold: -5°C to +55°C
• Trap status issue period: 24 hrs
• No password
• Luminosity: level 3
• 12 hr/24 hr mode: 24hr
• Eco mode: NOR
• ON & OFF time: 23 hrs OFF / 6 hrs ON
On the electronic board connector:
Green LED: network activity + power
Yellow LED: network type (ON = 100 m, OFF = 10 m)
IV
– Location of "S" and "+" keys
1) These two keys are located on the back of the clock:
– Right side: when viewed from the back
– Left side: when viewed from the front (when being handled)
2) The "S" key is above the "+" key.
3) When pressed, an LED lights up to indicate the selected key.
Example Style Mondiale 3 cities showing the two keys pressed simultaneously:
8
EN